LMVP single busbar panel

IEC 298 Single Busbar Panel

LMVP 12kV single busbar panel with withdrawable voltage transformer

12kV single busbar panel in a fixed enclosure with withdrawable voltage transformer options and IEC 298 internal arc certification highlights.

Technical Overview

LMVP 12kV single busbar panel with withdrawable voltage transformer

12kV single busbar panel in a fixed enclosure with withdrawable voltage transformer options and IEC 298 internal arc certification highlights.

Key Highlights

  • Fixed rigid sheet steel enclosure
  • Four-section panel layout
  • Air-insulated cable box
  • Guide-rail supported breaker compartment
  • Fixed, withdrawable, or primary-disconnectable VT options
IEC 298 LMVP single busbar panel
LMVP 12kV IEC 298 single busbar panel.
Technical Sections

Structured detail for IEC 298 Single Busbar Panel.

Overview

The IEC 298 single busbar panel is housed in a rigid fixed sheet steel enclosure. The enclosure is divided into the busbar and current transformer chamber, control cubicle, cable box, and circuit breaker compartment.

Busbar and Current Transformer Chamber

The busbar chamber contains three-phase copper busbars rated at 1250A, 2000A, 2500A, or 3000A. The rear section houses current transformers selected for the specification.

Current transformers may be low-voltage insulated and mounted on earthed screened primary bushings with silica-filled epoxy resin insulation. Bar primary or wound primary types can be used, and the transformers comply with IEC 61869-1 and IEC 61869-2.

Control Cubicle

The control cubicle houses relays, control equipment, protection relays, and instruments.

Cable Box

The air-insulated cable box supports heat-shrink cable terminations.

Circuit Breaker Compartment

The lower section houses the circuit breaker. Guide rails provide smooth, safe entry and removal while ensuring accurate location in the correct position.

Internal Arc Compliance (IEC 298)

LMVP certification highlights for this panel include A-FL at 20kA for 1 second and A-FLR at 25kA for 1 second, depending on installation conditions and ceiling height.

  • A-FL: 20kA for 1 second with 2.8m roof-right condition.
  • A-FLR: 25kA for 1 second with 4m ceiling height condition.

Withdrawable Voltage Transformer

Voltage transformers with silica-filled epoxy resin encapsulated primary windings can be supplied as fixed, withdrawable, or primary-disconnectable units. They can connect to the circuit or busbars and comply with IEC 61869-1 and IEC 61869-3.

Product Images

Additional LMVP reference image.

IEC 298 withdrawable voltage transformer
Withdrawable voltage transformer arrangement.
Next step

Need this LMVP configuration on a project?

Contact RPS Switchgear SA to align the technical requirement, panel configuration, ratings, testing, and field support scope.